Header Image SPF Kollektortestdach am OST-Campus Rapperswil

Publikation

Fault Inspection of CIGS PV Plant Using Aerial Infrared Thermography

Aerial infrared thermography (aIRT) is an efficient method to detect faults in PV installations. This work investigates the aIRT of a CIGS thin-film PV plant. The inspection of the 1 MWp plant of 1.4 hectares at 20 m altitude took about 12 minutes, plus 30 minutes for analysing the video data. Such an inspection allows the detection of most of the faults in a thin-film PV plant.

Autorenschaft:
D. Amstad, A. K. V. Oliveira, A. Häberle, R. Rüther, 2019
Zeitschrift / Sammelband:
EU PVSEC, Nr.36th/2019
Seiten / Kapitel:
1573-1578